The Atlas Copco ZR 30 VSD occupies a specific corner of the oil-free tooth range: it is the water-cooled 30 kW frame whose variable-speed documentation exists as a VSD\u207a machine, printed with two pressure classes on the same chassis. The catalogue’s water-cooled VSD table lists no standard 30 kW row at all \u2014 the ZR 37 VSD and ZR 55 VSD occupy the adjacent slots \u2014 so every ZR 30 VSD order is built on the VSD\u207a platform of the ZR\/ZT 30-50 family, with its permanent-magnet drive and both 8.6 and 10 bar(e) classes at 66 dB(A).<\/p>\n
For plants with cooling water on site, this concentrates the whole speed story into one tier and leaves the heat balance as the real design decision, because the water-cooled build can route recovered compression heat into a hot water circuit up to 90\u00b0C.<\/p>\n
The ZR 30 VSD\u207a \u2014 8.6 bar(e) Class<\/h2>\n
The 8.6 bar(e) class is measured across three rows with the motor rating printed once at 30 kW. At Minimum the machine opens at 4 bar(e) with 38\u201394 l\/s, at the Effective point of 7 bar(e) it holds 37\u201392 l\/s, and the Maximum row at 8.6 bar(e) closes at 36\u201372 l\/s. The m\u00b3\/min column runs 2.28\u20135.64 at Minimum and narrows to 2.16\u20134.32 at Maximum, and the noise level for the class is printed at 66 dB(A). In the imperial column the same class reads 58, 102 and 125 psig at the three points, with the drive rated at 40 hp.<\/p>\n
The ZR 30 VSD\u207a \u2014 10 bar(e) Class<\/h2>\n
The second class keeps the same starting band at Minimum but accepts a larger flow penalty at the pressure ceiling. Minimum stays at 38\u201394 l\/s over 4 bar(e), the Effective point at 9 bar(e) reads 37\u201392 l\/s, and the Maximum row at 10 bar(e) closes at 35\u201362 l\/s \u2014 a figure worth noting, because the 10 bar(e) ceiling takes away just over a quarter of this class’s top-end flow. The m\u00b3\/min column runs 2.28\u20135.64 down to 2.10\u20133.72, the noise level remains 66 dB(A), and the imperial column prints 58, 130 and 150 psig, the highest Maximum pressure figure in the 30-50 VSD\u207a family at this frame size.<\/p>\n
Energy Recovery Turns Compression Heat into 90\u00b0C Hot Water<\/h2>\n
Water cooling changes what happens to the heat that air-cooled frames must blow into the room. On the ZR 30 VSD the optional Energy Recovery control unit diverts recovered compression heat into a water circuit, and the documentation states that hot water temperatures up to 90\u00b0C can be achieved. For a food plant that runs wash-down stations or a pharmaceutical site with cleaning-in-place loops, that output replaces boiler duty that would otherwise burn fuel hour after hour.<\/p>\n
The recovery function is tied to the water-cooled version specifically, which is one of the practical reasons the 30 kW slot is documented as a water-cooled VSD\u207a machine rather than a generic air-cooled build. Sites without an immediate hot water consumer can still order the machine without the recovery option and gain the water-cooled acoustic benefit alone.<\/p>\n
Weights, Dimensions and the North American CAGI Sheet<\/h2>\n
Physically the ZR 30 VSD follows the family table shared across the 30 and 37 kW frames: 1350 kg packed, 1610 kg as Full Feature with the iMD dryer and 1504 kg as Full Feature with the iD dryer. The envelope is 2005 \u00d7 1022 \u00d7 1909 mm, extending to 2440 mm in length for the Full Feature build. The dryer column reads ID \/ IMD, so the integrated treatment choice is open on both pressure classes.<\/p>\n
North American buyers have an additional print to consult: the CAGI data sheet for the ZR 30 FLX VSD, dated 07-08-2025, lists a Drive Motor Nominal Rating of 40.2 & 40.2 hp at 96.3 percent efficiency, a full load operating pressure of 124.7 psig on the 8.6 bar(e) build and 145.0 psig on the 10 bar(e) build, capacity from 169.2 down to 74.9 acfm, and specific power from 21.9 to 25.0 kW per 100 acfm across the measured field of the 8.6 bar(e) sheet.<\/p>\n
The CAGI sheet itself can be summarised line by line, and the two builds share every motor figure while differing only in pressure and the flow field that follows from it. Reading the printed rows in order gives the table below, which is the quickest way to compare the two pressure classes against any other CAGI-listed machine at identical test conditions.<\/p>\n
The natural home for this machine is a facility that already circulates cooling water and needs oil-free air at one of two pressures. Breweries and dairies fit the profile exactly: the 8.6 bar(e) class serves general service air at 92 l\/s effective, while recovered heat at up to 90\u00b0C feeds cleaning loops that would otherwise run on steam or gas. Electronics plants with chilled water on site gain a different benefit \u2014 the water-cooled chassis holds the compressor room at 66 dB(A) without adding fan heat to the cooling load.<\/p>\n
Because the frame shares its weight and footprint table with the 37 kW build, a growing plant can plan the pit, pad and pipe sizing once and step up later without re-engineering the room. The absence of a standard VSD row at this size is not a limitation in practice, since the VSD\u207a tier already spans both pressure classes and carries the family’s permanent-magnet drive \u2014 points we confirm for each ZR 30 VSD enquiry against the load profile the buyer sends us.<\/p>\n
Questions Buyers Ask About the ZR 30 VSD<\/h2>\n
Why is there no standard VSD row for the water-cooled 30 kW frame?<\/strong> The catalogue’s water-cooled VSD table starts at the ZR 37 VSD, so the 30 kW build is documented exclusively on the VSD\u207a platform with its 8.6 and 10 bar(e) classes. Buyers who want the plain VSD drive at this size are directed to the air-cooled ZT30VSD instead.<\/p>\n
What temperature can the recovered hot water reach?<\/strong> The Energy Recovery documentation prints up to 90\u00b0C on the water-cooled version. The output is sized around the compression heat of the 30 kW drive, so a plant considering the ZR 30 VSD should compare its wash-down or CIP draw against that band before ordering the recovery unit.<\/p>\n
How does the 10 bar(e) class affect flow planning?<\/strong> The Maximum row of the 10 bar(e) class closes at 35\u201362 l\/s, against 36\u201372 l\/s on the 8.6 bar(e) class. Plants sizing a 10 bar(e) loop on the ZR 30 VSD should therefore work from the 62 l\/s ceiling rather than assuming the 8.6 bar(e) figures carry over unchanged.<\/p>\n